BRIEF ORIGINAL ARTICLE
REVISTA DE LA FACULTAD DE MEDICINA HUMANA 2024 - Universidad Ricardo Palma
1 Facultad de Ciencias Biológicas, Universidad Nacional Pedro Ruíz Gallo. Lambayeque, Peru.
2 Laboratorio de Investigación, Hospital Regional Lambayeque. Chiclayo, Peru.
a Bachelor of Biology
a Biologist. Master of Clinical Microbiology
ABSTRACT
The study aimed to describe the etiology and bacterial frequency on the cell phones of healthcare
personnel at the Hospital de Clínicas de Chiclayo, Peru, from March to August 2022. Thirty phones from
doctors, nurses, and technicians in hospitalization areas and the Intensive Vigilance Unit (IVU) were
analyzed. Samples were taken from the phone screens, cultured, and bacteria were identified using
biochemical tests. The data was recorded and analyzed with Microsoft Excel 2013. Bacterial colonization
was found on 56.7% of the phones: Gram-positive bacteria on 33.3% and Gram-negative bacteria on 23.3%.
Staphylococcus coagulase-negative (35.3%) and Escherichia coli (23.5%) predominated in hospitalization,
while Staphylococcus aureus (23.5%) predominated in the IVU. 66.7% of the personnel rarely disinfected
their phones, and 40% washed their hands infrequently. Staphylococcus coagulase-negative, S. aureus, and
E. coli were the most frequent agents, suggesting deficiencies in hospital hygiene practices.
Keywords: Smartphone; Health Personnel; Hospitals, Private (source: MeSH NLM)
RESUMEN
El estudio buscó describir la etiología y frecuencia bacteriana en los teléfonos celulares del personal
de salud en el Hospital de Clínicas de Chiclayo, Perú, de marzo a agosto de 2022. Se analizaron 30
teléfonos de médicos, enfermeros y técnicos en áreas de hospitalización y Unidad de Vigilancia Intensiva
(UVI). Se tomaron muestras de las pantallas, se cultivaron y se identificaron las bacterias mediante
pruebas bioquímicas. Se registró y analizó la información con Microsoft Excel 2013. El 56,7 % de los
teléfonos presentó colonización bacteriana: Gram positivas en 33,3 % y Gram negativas en 23,3 %.
Predominaron Staphylococcus coagulasa negativa (35,3 %) y Escherichia coli (23,5 %) en hospitalización,
y Staphylococcus aureus (23,5 %) en UVI. El 66,7 % desinfectaba los teléfonos poco y el 40 % lavaba las
manos con poca frecuencia. Staphylococcus coagulasa negativa, S. aureus y E. coli fueron los agentes más
frecuentes, sugiriendo deficiencias en la higiene hospitalaria
Palabras clave: Teléfono Inteligente; Personal de Salud; Hospitales Privados (fuente: DeCS-
BIREME)
INTRODUCTION
Currently, communication through cell phones has become a necessity in our lives, with 94.9% of Peruvian
households having at least one member with such a device, and 89.3% of the population aged six and older
accessing the internet through their cell phones (1). These devices are also
used in work activities by students and healthcare personnel, who, when interacting with human skin,
bags, the environment, and food, contaminate them with pathogenic microorganisms (2). This constitutes a significant risk, as cell phones act as reservoirs
and fomites for the transmission (3) of bacteria, fungi, viruses, and
resistance genes (4).
The use of cell phones in hospital environments is a common practice among healthcare personnel,
representing a potential source of transmission for Staphylococcus aureus (85.7%) and Escherichia coli
(61.9%) (5). There have also been reports of coagulase-negative
Staphylococcus sp. (SCON) (6), Enterobacter aerogenes, and Klebsiella
species isolated from cell phones of nursing and medical students (7). This
situation is due to the fact that the hands of healthcare workers and their phones are often (2 - 4) contaminated with one or more types of
microorganisms, both sensitive and resistant, due to the lack of disinfection among healthcare
professionals. Therefore, the objective of this study was to describe the etiology and frequency of
bacterial contamination on the cell phones of healthcare personnel at a clinic in Chiclayo.
Methods
The study was observational, descriptive, and cross-sectional. It was conducted at the Hospital de
Clínicas, located in Chiclayo, a city in the northern region of Peru. This hospital is a private,
high-complexity healthcare facility with capacity for care in various specialties.
Information was obtained from healthcare personnel working in hospitalization areas and the Intensive
Care Unit (ICU) during the period from March to August 2022. A non-probabilistic sampling of 30 cell
phones (Huawei Y9, Huawei P30Lite, Huawei Y7P, Redmi Note 9, Xiaomi 11Lite, Oppo A38, iPhone, Samsung
S10 and Samsung Galaxy: Note 8, S10, A04, A12, A15, A25, A30s, A32) voluntarily provided by healthcare
personnel (comprising doctors, nurses, and technicians) was performed. Only subjects who performed care
duties and had direct contact with patients were selected; those performing administrative functions
were excluded.
Data collection began with the completion of informed consent and the survey by healthcare personnel in
the hospitalization and ICU areas, who voluntarily agreed to participate. Subsequently, sample
collection was carried out.
The sample collection procedure followed the method of Alvarado, Muñoz, and Zavaleta (2018) (Ezpeleta et
al. (8)). In the hospitalization and ICU areas, a work area was disinfected
with 70% alcohol. The owners were asked to place their cell phones in a Ziploc bag with a code. During
sample collection, two alcohol burners separated by 20 cm were used to maintain a sterile space. The
touch screens of the phones were swabbed over an area of 5 cm², wetting the sterile swab in BHI medium.
The swab head was placed in a test tube with BHI medium and transported to the laboratory in a thermal
container to be incubated at 37 °C for 24 hours. After sample collection, the phones were cleaned with
gauze moistened with 70% isopropyl alcohol and returned to their owners.
The samples in BHI medium were incubated at 37 °C for 24 hours. Turbidity in the tubes indicated
bacterial growth. They were then re-streaked on Blood Agar, MacConkey Agar, Mannitol Salt Agar, and
Cetrimide Agar plates, incubated at 37 °C for 24 hours. The recommendations of the Manual of
Bacteriological Procedures in Nosocomial Infections and the interpretations of biochemical reactions
were followed according to the guidelines of Farmer et al. (9).
For identification, Gram staining of incubated colonies was performed to observe bacterial morphology.
They were then transferred to a cryovial with appropriate culture medium, incubated at 37 °C for 24
hours. Biochemical tests were then performed for bacterial identification.
For Gram-positive bacteria, the catalase test was used: a sample of the pure culture was placed on a
slide with 10% hydrogen peroxide. Bubbles observed within 10-20 seconds indicated a positive test. In
the coagulase test, a blood sample was centrifuged at 4,000 rpm for five minutes to obtain citrated
plasma. 500 µL of plasma was placed in a sterile tube with a sample of the pure culture and incubated at
37 °C, with clot formation observed every 30 minutes for four hours.
For Gram-negative bacteria, the oxidase test was performed: a sample of the pure culture was placed on a
strip of paper with oxidase reagent for 10-60 seconds. A violet color indicated a positive reaction.
Fermentation tests were conducted using media such as Simmons Citrate, Lysine Iron Agar (LIA), Motility
Indole Ornithine (MIO), and Triple Sugar Iron Agar (TSI). Pure culture was inoculated by stabbing or
streaking and incubated at 37 °C for 24 hours for subsequent reading.
The information obtained from the surveys and cultures was recorded in a Microsoft Excel 2013 electronic
template. Quality controls were performed using filters and variable verification. Data were expressed
in tables with absolute and relative frequencies. Authorization was requested from the director of
Hospital de Clínicas Lambayeque SAC for project execution in the laboratory area. Healthcare personnel
were also interviewed to fill out informed consent forms, allowing the use of their cell phones in the
research.
Results
Of the healthcare personnel evaluated, 60% were female and 40% male. Nursing personnel predominated,
representing 46.7% of the total. Of the cell phones analyzed, 56.7% showed bacterial colonization, with
the presence of Gram-positive and Gram-negative bacteria in 33.3% and 23.3% of the devices, respectively
(Table 1).
Characteristics |
Frequency |
Percentage (%) |
|||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sex |
|
|
|||||||||
Male |
12 |
40 |
|||||||||
Female |
18 |
60 |
|||||||||
Healthcare personnel |
|
|
|||||||||
Doctors |
7 |
23,3 |
|||||||||
Nurses |
14 |
46,7 |
|||||||||
Nursing technicians |
9 |
30 |
|||||||||
Work areas |
|
|
|||||||||
ICU |
11 |
36,7 |
|||||||||
Hospitalization |
19 |
63,3 |
|||||||||
Cell phone colonization |
|
|
|||||||||
Not contaminated |
13 |
43,3 |
|||||||||
Contaminated |
17 |
56,7 |
|||||||||
Isolated microorganism |
|
|
|||||||||
Gram-positive |
10 |
33,3 |
|||||||||
Gram-negative |
7 |
23,3 |
|||||||||
None |
13 |
43,3 |
The predominant microorganisms in the 17 contaminated cell phones were SCON and E. coli with 35.3% and
23.5%, respectively, which originated from the devices of personnel working in the hospitalization area.
Staphylococcus aureus was isolated only in the ICU area (23.5%), while Pseudomonas aeruginosa was
isolated in both the hospitalization and ICU areas (Table 2).
Microorganisms |
ICU |
Hospitalization |
|||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
n |
% |
n |
% |
||||||||||||||||
Coagulase-negative Staphylococcus sp. |
0 |
0,0% |
6 |
35,3% |
|||||||||||||||
Staphylococcus aureus |
4 |
23,5% |
0 |
0,0% |
|||||||||||||||
Escherichia coli |
1 |
5,9% |
4 |
23,5% |
|||||||||||||||
Pseudomonas aeruginosa |
1 |
5,9% |
1 |
5,9% |
UVI: Unidad de Vigilancia Intensiva
The survey on the habits of healthcare personnel and cell phone use reveals that before work, 43% (13)
use it frequently and 56.7% (17) very frequently. During work, 46.7% (14) use it infrequently and 53.3%
(16) frequently. In restrooms, 26.7% (8) use the phone infrequently and 73.3% (22) never use it. For
disinfection, 66.7% (20) do it infrequently and 33.3% (10) frequently. Regarding hand washing, 40% (12)
do it infrequently and 60% (18) frequently (Table 3).
Work habits |
Frequency |
||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Never |
Occasionally |
Regularly |
Habitually |
||||||||||||||||
n (%) |
n (%) |
n (%) |
n (%) |
||||||||||||||||
Uso of cell phone before work |
0 (0) |
0 (0) |
13 (43,3) |
17 (56,7) |
|||||||||||||||
Uso of cell phone during work |
0 (0) |
14 (46,7) |
16 (53,3) |
0 (0) |
|||||||||||||||
Uso of cell phone in restrooms |
22(73,3) |
8 (26,7) |
0 (0) |
0 (0) |
|||||||||||||||
Frequency of disinfection |
0 (0) |
20 (66,7) |
10 (33,3) |
0 (0) |
|||||||||||||||
Frequency of hand washing |
0 (0) |
12 (40,0) |
18 (60,0) |
0 (0) |
DISCUSSION
The results confirm the presence of pathogenic Gram-positive and Gram-negative bacteria on the cell
phones evaluated. Similar findings have been reported in students from a public university (6), where different environmental surfaces can serve as potential reservoirs
for nosocomial pathogens and facilitate their transmission by contact, depending on their tenacity. Many
microorganisms can survive on inanimate surfaces for days, weeks, and even months, increasing the
likelihood of transmission within a healthcare facility (10).
Bacterial contamination on the evaluated phones was 56.7%. These results differ from the 100%
colonization in 40 cell phones analyzed in a university hospital in Egypt and the 84.8% in 50 phones of
healthcare personnel in Huancayo, Peru (11). In hospitals in Spain,
contamination was 49.5%, demonstrating that these devices are used without restrictions for disinfection
and, therefore, constitute a source of transmission of pathogenic bacteria with the risk of causing
nosocomial infections (12).
The most frequent isolates in the study were SCON and Escherichia coli, with 35.3% and 23.5%,
respectively. Similar reports indicate a prevalence of 40% and 28.7% in Huancayo (11) and 37.5% of SCON, and 24.4% of Enterobacteriaceae in Trujillo (13). In Lima, 93.5% of SCON, 6.5% of Staphylococcus aureus, and 11.1% of E.
coli were isolated (6). These findings are comparable to Santana-Padilla's
study (12), albeit with slight differences in isolation frequency, who
obtained growth of Pseudomonas aeruginosa (12.5%) and methicillin-resistant S. aureus (10.9%). These
data highlight that the use of cell phones, while offering communication and information access
advantages, also presents the disadvantage of being a potential source for the spread of pathogenic
bacteria in the hospital environment.
The predominance of SCON among the identified isolates is due to their normal presence as part of the
skin microbiota. When hands interact with the cell phone, an opportune microenvironment is created for
their proliferation (14). Bacteria survive and persist on various inanimate
surfaces such as metal, fabric, plastic, wood, and ceramic (15), as well as
on medical devices, cell phones, and computers in critical units (16). This
capability is due to cell wall-anchored proteins of Staphylococcus that allow adherence to inert
material (14), or in the case of P. aeruginosa, forming biofilms with
alginate, PSL, and PEL exopolysaccharides (17). Therefore, the hospital
environment is highly contaminated by pathogenic microorganisms, related to their survival time and the
cleaning and disinfection processes (18).
The evaluation highlighted the use of cell phones before and during work activities with infrequent
disinfection by healthcare personnel. Similar results occurred in healthcare workers in two hospitals in
Brazil, who claim to be sufficiently trained but do not follow standard practices (19). This attitude also occurs in students interacting with patients. This
reality highlights the non-compliance with standard precautions aimed at protecting and ensuring safe
care. Good hand hygiene practices, asepsis, and the use of personal protective equipment prevent
nosocomial infections (20). Therefore, compliance with these safety
measures requires special attention due to the risk posed by the presence of infectious pathogens for
patients, visitors, and healthcare workers.
As a study limitation, it was not possible to carry out several measures that would have allowed
evaluating the variation in cell phone contamination at different times. Additionally, antimicrobial
susceptibility was not performed, so the resistance pattern and some resistance mechanisms are unknown.
However, comparative studies of bacterial isolates from cell devices and the hands of healthcare
personnel are recommended to establish associations and raise awareness among staff about the importance
of complying with hygiene and biosafety practices.
In conclusion, SCON, S. aureus, and E. coli were the most frequently isolated etiological agents on cell
phone surfaces of healthcare personnel working in the ICU and hospitalization areas of a hospital in
Chiclayo. The high percentage of contamination by pathogenic and opportunistic bacteria could be due to
non-compliance with good hygiene practices by healthcare personnel in the hospital environment.
Authorship contributions:
AACC and GAGV participated in the conception, design, and data analysis, as well as the
writing and interpretation of results. RVF participated in the review of the initial draft
and the analysis and interpretation of data. All authors contributed to the writing of the
article, critical review, and approval of the final version.
Financing:
Self-funded
Declaration of conflict of interest:
The authors declare no conflicts of interest.
Recevied:
October 7, 2023
Approved:
January 2, 2024
Correspondence author:
Roberto Ventura-Flores.
Address:
Cuidad Universitaria Facultad de Ciencias Biológicas. Av. Juan XXIII Nº 391 Lambayeque,
Perú.
Phone:
(+51) 979008615
E-mail:
rventuraf@unprg.edu.pe
Article published by the Journal of the faculty of Human Medicine of the Ricardo Palma University. It is an open access article, distributed under the terms of the Creatvie Commons license: Creative Commons Attribution 4.0 International, CC BY 4.0 (https://creativecommons.org/licenses/by/4.0/), that allows non-commercial use, distribution and reproduction in any medium, provided that the original work is duly cited. For commercial use, please contact revista.medicina@urp.edu.pe.